No, the annubar is a different kind of differential pressure sensor; It is essentially a multiple pitot tube, which requires a different kind of calculation than an orifice plate....
Lire la suiteYou cannot download a new .AFC file while any of the meter runs are enabled, or illegal data values will be reported by AFC manager.First you must disable all meter runs. This can be done either using the AFC manager, or the easier way is through the ladder logic. Once the meter ...
Lire la suiteProSoft AFC flow computer modules implement the Bernoulli equation for measurement of fluid flow through concentric square-edged orifices. The Coefficient of Discharge in this equation is calculated by an appropriate Standard, which may, by option selection, be chosen as either A...
Lire la suiteFirst of all, be sure your processor is showing Local Time and that you have run the "Set Clock" routine from the AFC logic to synchronize the MVIxx-AFC Wallclock to the processor time.If the processor shows correct local time and the MVIxx-AFC shows GMT after the ...
Lire la suiteFor Vortex, Ultrasonic or Coriolis meters, the selection depends on the output generated bythe meter. If the meter provides a pulse train representing the volume increment, the AFC meter should beconfigured as Linear with Primary Input selected as Pulse Count. If t...
Lire la suiteThe short answer is, "No, it cannot." The reason it cannot is this:ISO 6976 is the ISO standard for calculating compressibilities and energy content of natural gases. It is similar to the older (pre-1992) edition of AGA 8 (compressibilities) and the current ...
Lire la suiteThe Multiple Meter Streams options can be used to more efficiently compute flows through a single meter at a physical site that has different fluids flowing through the meter at different times. Since each Stream will have it's own meter configurati...
Lire la suiteIf there is no analysis available, the user must supply in the meter configuration a suitable default relative density (= specific gravity), the density of the gas relative to air at the reference conditions.</?xml:namespace>If there is an analysis available (such...
Lire la suiteOn bottom of the circuit board for any MVI products, you' ll find three jumper banks: COM1, COM2, and Setup.Each jumper position is labeled 232, 422 and 485....
Lire la suiteThe API-11 and API-12 calculations are available in ProSoft AFC Flow Computers, beginning with version 2.05. MPMS Ch 12 specifies, essentially, the necessary factors and calculational sequence for measuring liquids, and the general method of measurement using ...
Lire la suiteThe two application serial ports provide 1000 volts of electrical isolation between the port and the ControlLogix backplane.The debug/configuration port provides no electrical isolation. Note: None of the ports provide any electrical isolation between the port and the module's i...
Lire la suiteThe AGA Specifications include Part 1 "General Equations and Uncertainty Guidelines", dated 1990; Part 2 "Specification and Installation Requirements", dated 2000; Part 3 "Natural Gas Applications", dated 1992; and Part 4 "Background,...
Lire la suiteThe attached document describes the differences in the calculations when using AGA 3....
Lire la suiteThe AFC is not designed to receive a corrected flow input.However if the AFC is being used only for its accumulation and archive capabilities, then rather than the process temperature and pressure inputs, provide the meter's reference conditions as the AFC's temperature and press...
Lire la suite