• English
  • 中文
  • Français
  • Deutsch
  • Español
Contact Us
Home
Email
Follow Prosoft Technology on Twitter
Follow Prosoft Technology on Facebook
Follow Prosoft Technology on LinkedIn
Follow Prosoft Technology on YouTube
    • PROFINET Controller Module for ControlLogix®
    • EtherNet/IP™ to DH+ Gateway
    • Two-Port Building Automation Gateway
  • Solutions
    • Amusement
    • Automated Material Handling
    • Automotive
    • IIoT Solutions
    • Mining and Metals
    • Modernization
    • Oil and Gas Solutions
    • Secure Remote Connectivity
    • Water & Wastewater
  • Produits
    • Accès à distance
    • Solutions Rockwell Automation en châssis
    • Passerelles Autonomes
    • Sans fil industriel
    • Logiciels ProSoft
  • SERVICES ET SUPPORT
    • Knowledge Base
    • Support Technique Local
    • Téléchargements
    • Formation
    • Return Material Instructions
    • Documentation
  • ACTUALITÉS
    • ProSoft Insights (Blog)
    • Podcast
      Knowledge Base / Rockwell In-chassis / ControlLogix / MVI56 Series

      MVI56-MNETC

      Search KB

      Catégories

      • Gateways
      • Rockwell In-chassis
        • Programmable Modules
        • CompactLogix
        • ControlLogix
          • MVI56E Series
          • MVI56 Series
            • MVI56-DNPSNET
            • MVI56-AFC
            • MVI56-MNETC
            • MVI56-GEC
            • MVI56-DNP
            • MVI56-104S
            • MVI56-PDPMV1
            • MVI56-MNET
            • MVI56-DFCM
            • MVI56-MCM
            • MVI56-BAS
            • MVI56-GSC
        • MVI94 - Flex I/O
      • Schneider In-chassis
      • Wireless
      • Accessories
      • Protocols
      • Software
      • Legacy Products
      • Certifications
      • Technical Support
      • Miscellaneous

      Browse Categories

      What causes a conditional command to be issued?

      A conditional command is useful when the same value does not need to be written to the end device continuously, but rather on change. A conditional write command is scanned based upon its poll rate (like all other commands).  The difference is that it will not be execut...

      Lire la suite

      What does a -36 modbus error code indicate?

      A negative thirty six (-36) error code is generated when we have successfully connected to a device and issued the device a Modbus request, but it has not responded to the request within the defined response time out period. This is akin to calling some one on the phone, having s...

      Lire la suite

      What is Enron-Daniels mode?

      In some of our older Modbus products we had/have a feature called float flag. This feature, which has been renamed to Enron-Daniels mode in most of our newer Modbus products to avoid the misconception that this mode was necessary for accessing floating point values in non-Enron o...

      Lire la suite

Solutions

  • Amusement
  • Automated Material Handling
  • Automotive
  • IIoT Solutions
  • Mining and Metals
  • Modernization
  • Oil and Gas Solutions
  • Secure Remote Connectivity
  • Water & Wastewater