ProSoft Insights / Points techniques

Saviez-vous que le protocole ProSoft Siemens Industrial Ethernet peut être utilisé avec les S7-1500 CPU?

Rechercher

Catégories

Tags

Subscribe

Yes, I would like to receive marketing information from ProSoft Technology, Inc., and its affiliates, subsidiary companies and brands indicated below.

I therefore provide my consent to the use of the personal information submitted here for the purpose of providing me marketing information related to ProSoft Technology, Inc. and its affiliates’ and subsidiaries’ products, services and marketing events. I understand that I may withdraw my consent at any time. Additional information regarding ProSoft’s data privacy policies, including how to withdraw this consent, is available at www.prosoft-technology.com/privacy. ProSoft Technology, Inc. is a subsidiary of Belden Inc., and their affiliates, subsidiary companies and brands include ProSoft Technology SAS, ProLinx Comunicacao Industria, LTDA; Global Blue Networks Inc., and ProSoft Technology (Asia Pacific) SDN BHD.

Articles récents

MQTT’s Role in IT/OT Convergence

30 oct, 2024 / Points techniques

IT’s data can play a major role in OT’s processes, ensuring goals are met and issues ar...

What Do You Need to Modernize? This Superstar Gateway Can Help

16 oct, 2024 / Infos produits

We’d like to think that the AN-X4 modernization gateway is something of a superstar sol...

Should You Use Cellular or Wi-Fi to Connect AMRs and AGVs?

12 sept, 2024 / Points techniques

The demands on logistics facilities and material handling applications remain supersize...

Transform Your Water and Wastewater Application’s Connectivity

21 août, 2024 / Points techniques

Legacy connectivity in water and wastewater operations includes two major communication...

Saviez-vous que le protocole ProSoft Siemens® Industrial Ethernet peut être utilisé avec les S7-1500 CPU?

Le protocole de communication Siemens® Industrial Ethernet opère tel un client. En effet, il initie la communication avec les CPU S7-1500 dans le but de lire et écrire des données dans le contrôleur.  

A l’instar d’un S7-1200, le S7-1500 possède un mécanisme de protection empêchant certains équipements d’échanger des données avec la CPU.  Cette fonctionnalité peut-être implémentée directement via TIA Portal (le logiciel de programmation dédié aux S7). Par défaut, l’option "Connection mechanisms" est décochée.

En cochant cette option, vous permettez au driver ProSoft SIE de communiquer avec la CPU du S7-1500.