The PLX51-PBS gateway provides connectivity to EtherNet/IP™, Modbus® TCP/IP, or Modbus® Serial networks for PROFIBUS DP networks by operating as a PROFIBUS DP slave.
For easy integration to a Rockwell Automation Controller, the gateway and configuration software create dynamic AOI’s based on the user configuration to add logical tag names to the PLC project file. Thus, reducing programming time.
For configuration of Modbus TCP/IP or Modbus Serial Networks, the module will automatically map PROFIBUS DP data points to registers on a Modbus network.
With advanced tools such as a built in PROFIBUS DP packet capture utility, PROFIBUS DP network commissioning time can be greatly reduced.
Dual Ethernet ports of the module can support either DLR (Device Level Ring) topology, or can be used as an embedded switch for flexible installation options.
With support for up to 1536 bytes of Input and Output data, and up to 4 EtherNet/IP connections back to the processor, this module provides performance and data throughput for even the most demanding of PROFIBUS applications.
As a PROFIBUS DP slave device, the module can emulate from 1 to as many as 10 slave DP nodes, providing up to 1536 bytes of Input and Output Cyclic I/O data between EtherNet/IP devices and a PROFIBUS DP master. This eliminates the need for using DPV1 messaging when more than 244 bytes of data needs to be exchanged between a PROFIBUS master and an EtherNet/IP network.
A conformal coating option is available for this product.
The PLX50 Configuration Utility software is used for configuration and troubleshooting of the module. The stand-alone configuration utility allows users to define the setup and configuration of the PROFIBUS DP module, connections with Rockwell Automation controllers and devices over EtherNet/IP, and build custom Add-On Instructions (AOIs) to be imported into Studio 5000 applications.
With the ability to import custom AOI’s into the Studio 5000 environment and advanced PROFIBUS DP tools such as the packet capture utility, commissioning time of a network can be greatly reduced.
As an EtherNet/IP server, the gateway can support up to 4 Class 1 I/O connections back to a Controller on an EtherNet/IP network. Additionally, the server can respond to Class 3 messages from an EtherNet/IP client for the transfer of Status and PROFIBUS DP data.
As an EtherNet/IP client, the module can generate Get Attribute, Set Attribute, Set Static, or Custom messages using either Class 3 messaging or UCCM messaging on EtherNet/IP. With support for up to 5 unique devices on one module and a total of up to 50 mapping functions, this functionality allows EtherNet/IP devices such as Overload Protection Relays and Variable Frequency Drives to be mapped onto a PROFIBUS DP network.
On a Modbus TCP/IP network, the module will operate as either a Modbus TCP/IP Client or Server device.
As a Modbus TCP/IP client the module can be configured to automatically read/write all PROFIBUS DP data with a slave device for easy setup and configuration, or the Modbus Auxiliary Map feature will allow you to configure data transfer to customize the mapping to meet specific application requirements.
As a Modbus TCP/IP Server all information from the PROFIBUS DP network is stored in continuous registers in the module for easy configuration and efficient mapping of data to a Modbus TCP/IP client.
On a Modbus Serial network the module will operate as either a Master or a Slave device supporting either RS232 or RS485 communication networks.
As a Modbus Serial Master the module can be configured to automatically read/write all PROFIBUS DP data with a slave device for easy setup and configuration, or the Modbus Auxiliary Map feature will allow you to configure data transfer to customize the mapping to meet specific application requirements.
As a Modbus Serial Slave all information from the PROFIBUS DP network is stored in continuous registers in the module for easy configuration and efficient mapping of data to an attached master device.
The PROFIBUS DP-V0 Slave driver provides a powerful and easy-to-use interface between a PROFIBUS DP network and other networks.
This slave implementation emulates up to 10 individual nodes on a PROFIBUS DP network. It allows access to up to 1536 bytes of cyclic PROFIBUS Input data and up to 1536 bytes of cyclic PROFIBUS Output data.
For installations that require more than the 244 byte max cyclic PROFIBUS DP data exchange, this module allows users to emulate up to 10 nodes, eliminating the need for complex DPV1 Read/Write messages to a PROFIBUS DP node while improving data throughput.
EtherNet/IP™ |
|
Connector |
RJ45 |
Conductors |
CAT5 STP/UTP |
ARP Connections |
Max 40 |
TCP Connections |
Max 40 |
CIP Connections |
Max 10 |
Communication Rate |
10/100Mbps |
Duplex Mode |
Full / Half / Auto Negotiate |
Auto MDIX |
Yes |
Modbus TCP/IP |
|
Mode |
Client or Server |
Connector |
RJ45 |
Conductors |
CAT5 STP/UTP |
ARP Connections |
Max 40 |
Communication Rate |
10/100 Mbps |
Duplex Mode |
Full / Half / Auto Negotiate |
Auto MDIX |
Yes |
Modbus Serial |
|
Mode |
Master or Slave |
Media |
RS232 or RS485 |
Baud Rate |
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
Data Bits |
8 |
Stop Bits |
1 |
Parity |
None, Odd, Even |
PROFIBUS DP |
|
Protocol |
PROFIBUS DP Slave |
Baud Rate |
9600, 19.200, 45.5 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, 1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps |
Support |
DPV0 or DPV1 |
Cyclic I/O data |
Input: 1536 bytes Output: 1536 bytes |
Stop bits |
1 |
Specification |
Description |
Emissions |
IEC 61000-6-4 |
ESD Immunity |
EN 61000-4-2 |
Radiated RF Immunity |
IEC 61000-4-3 |
EFT/B Immunity |
IEC 61000-4-4 |
Surge Immunity |
IEC 61000-4-5 |
Conducted RF Immunity |
IEC 61000-4-6 |
Specification |
Description |
Enclosure Rating |
IP20, NEMA/UL Open Type |
Temperature |
-20 to 70 °C |
Earth Connection |
Yes, terminal based |
Dimensions (H x W x D) |
5.86 x 1.33 x 4.56 in |
Power Requirements |
Input: 10 to 36V DC |
Power Consumption |
85mA @ 24V => 2.04W |
Power Connector |
3-way terminal |
Conductors |
24 to 18 AWG |
ATEX Letter of Conformity | 278,54 kB | Dernière Modification 12/05/2022 |
CB Safety | 1,97 MB | Dernière Modification 04/09/2019 |
UL/cUL; Class1, Div 2 | 235,70 kB | Dernière Modification 04/09/2019 |
ODVA EtherNet/IP Declaration of Conformity | 37,88 kB | Dernière Modification 04/09/2019 |
Declaration of REACH Compliance | 128,14 kB | Dernière Modification 16/11/2022 |
Declaration of Conformity (RoHS/CE) | 139,57 kB | Dernière Modification 16/11/2022 |
Country Approval - Korea - KC Registration | 281,75 kB | Dernière Modification 12/05/2022 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1,92 MB | Dernière Modification 11/02/2022 |
Korean KC Registration | 281,75 kB | Dernière Modification 28/04/2022 |