ProSoft Technology’s Modbus® TCP/IP to Siemens Industrial Ethernet gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP controllers and Siemens® S7-400, S7-300, S7-200, S7-1200, and S7-1500 PACs.
In addition, the gateway includes several features, including data prioritization, that allow for simplified integration, reduced commissioning time and optimized performance.
The IEC 60870-5-104 Server Communication Module allows compatible processors to interface easily with IEC 60870-5-104 protocol-compatible hosts. Developed under license from Schneider Electric, the module incorporates proprietary backplane technology that enables powerful data access to the Quantum processor.
The PTQ-104S module acts as an input/output module between the IEC-60870-5-104 Ethernet network and the processor. Data transfer between the module and the processor is asynchronous from the actions on the network. Databases are defined by the user for the module to hold data as required by the protocol.
The DNP 3.0 Server over Ethernet with Quality Flag supports the implementation of the DNP 3.0 (Distributed Network Protocol) over Ethernet, allowing Quantum processors to easily communicate with host systems supporting the protocol. The module supports DNP Subset Level 2 features and some Level 3 features. The addition of the Quality Flag helps to insure data reliability for critical or time sensitive communication.
The HART Multi-drop Network Interface Module is a backplane-compatible module that allows Quantum processors to interface easily with HART compatible devices. Devices commonly supporting the protocol include pressure, temperature, flow transmitters, as well as other similar instruments commonly found in the process (and other) industry.
HART® is a registered trademark of the HART Communication Foundation
Le module PROFIBUS DPV1 Maître constitue une puissante interface de communication pour les processeurs Quantum®. Développé sous licence de Schneider Electric, le module comprend une technologie de fond de panier propriétaires qui permet de puissants échanges de données avec les processeurs.
Le module supporte les spécifications Maître complètes conformément à la norme internationale IEC 61158. Les données de paramètres acycliques peuvent être transmises au moyen de services DPV1 Classe 1 ou Classe 2, pour que les processeurs puissent aisément communiquer avec des équipements esclaves supportant le protocole PROFIBUS DPV0/V1.
Le module agit en tant que module d'entrée/sortie entre les réseaux PROFIBUS et le processeur. Le transfert de données à partir du processeur est asynchrone des transmissions de données d'E/S sur le réseau PROFIBUS.
The PROFIBUS DP Slave module is a powerful communication interface for Unity and Quantum platform processors that allows you to interface easily with a PROFIBUS DP Master device. Developed under license from Schneider Electric, the module incorporates proprietary backplane technology that enables powerful data exchange with Unity and Quantum processors.
La famille des points d'accès industriels RLX2 fournit des solutions sans fil sécurisées pour des applications d'automatisation en intérieur et en extérieur, pour des SCADA, pour des systèmes de contrôles et des travailleurs mobiles sur des infrastructures Wi-Fi. Elle opère dans les bandes de 2,4 ou 5 GHz, y compris les canaux DFS, et fonctionne pour des applications jusqu'à 2 miles (3,2 km).
Ces points d’accès industriels supportent les modes Point d’accès, répéteur, et client. La technologie 802.11n permet des vitesses de transmission élevées jusqu'à 300 Mbps. Ceci permet d’obtenir d’excellentes performances en termes de paquets par seconde et fournit toute la robustesse et la facilité de déploiement requises pour les applications industrielles.
La technologie 802.11n, MIMO (Multiple Inputs, Multiple Outputs) et canal large (40MHz), est adaptée pour des applications sans fil exigeantes telles que l’Ethernet I/O et pour de la vidéo haute résolution.
Le logiciel IH Browser de configuration et de surveillance, inclus avec chaque radio, permet à l’utilisateur de visualiser la topologie du réseau, d’attribuer des adresses IP, de surveiller les diagnostiques réseaux, et de mettre à jour le firmware de la radio.
L’option « OPC Diagnostic Server » est idéale pour la gestion de réseaux SCADA sans fil longue portée.
ProSoft Technology’s Modbus® TCP/IP to Siemens Industrial Ethernet gateway allows high speed bi-directional data transfers between Schneider Electric® PACs and Siemens S7 and S5 PACs.
Two ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address.
La passerelle autonome Modbus TCP/IP vers PROFINET permet un transfert bidirectionnel des données entre des équipements installés sur des réseaux PROFINET et des réseaux Modbus TCP/IP.
Le driver Modbus TCP utilise de multiples connexions client et server pour de meilleures performances. Le driver PROFINET agit en tant que station (device ou serveur).
La passerelle PLX31-MBTCP-PND est équipée d’un port Ethernet pour la communication, la configuration et le diagnostic. Une carte SD peut être utilisée pour stoker la configuration ou copier la configuration d’une passerelle à une autre (carte SD disponible en option).
La passerelle autonome Modbus® TCP/IP vers PROFINET® permet un transfert bidirectionnel des données entre des équipements installés sur des réseaux PROFINET et des réseaux Modbus TCP/IP.
Le driver Modbus TCP utilise de multiples connexions client et server pour de meilleures performances. Le driver PROFINET agit en tant que station (device ou serveur).
La passerelle PLX32-MBTCP-PND est équipée de deux ports Ethernet pour la communication, la configuration et le diagnostic. Une carte SD peut être utilisée pour stoker la configuration ou copier la configuration d’une passerelle à une autre (carte SD disponible en option).
La passerelle autonome EtherNet/IP™ vers PROFINET® IO permet un transfert bidirectionnel des données entre des équipements installés sur des réseaux PROFINET IO et des réseaux EtherNet/IP. Elle se monte sur rail DIN.
Cette passerelle détient plusieurs fonctionnalités qui permettent une intégration simplifiée, la réduction du temps de mise en service et de meilleures performances.
Une carte SD (optionnelle) peut être utilisée pour stocker la configuration qui peut ainsi être utilisée en cas de changement de passerelle ou à des fins de stockage de sureté.
La passerelle autonome EtherNet/IP™ vers PROFINET® permet un transfert bidirectionnel des données entre des équipements installés sur des réseaux PROFINET et des réseaux EtherNet/IP. Elle se monte sur rail DIN. La passerelle PLX32-EIP-PND est équipée de deux ports Ethernet, chaque port se connectant sur un réseau séparé. Le driver EtherNet/IP utilise des connexions de classe 1 (E/S) ou de classe 3 (instruction message). Le driver PROFINET agit en tant que station PROFINET de classe A. Une carte SD (optionnelle) peut être utilisée pour stocker la configuration qui peut ainsi être utilisée en cas de changement de passerelle ou à des fins de stockage de sureté. |
Le point d’accès industriel rapide 802.11abgn IP67 étanche de ProSoft Technology (RLX2-IHNF-W) est conçu pour les environnements difficiles. Il est certifié IP66/67.
Il est étanche à l'eau pour une utilisation dans des applications météorologiques extrêmes telles que les plates-formes pétrolières en mer, et étanche à la poussière pour une utilisation dans les applications minières.
Il opère dans les bandes 2,4 ou 5 GHz, y compris les canaux DFS, et fonctionne pour des applications jusqu'à 3,2 km (2 miles).
Ces points d’accès industriels supportent les modes Point d’accès, répéteur, et client. La technologie 802.11n permet des vitesses de transmission élevées jusqu'à 300 Mbps. Ceci permet d’obtenir d’excellentes performances en termes de paquets par seconde et fournit toute la robustesse et la facilité de déploiement requises pour les applications industrielles.
La technologie 802.11n, MIMO (Multiple Inputs, Multiple Outputs) et canal large (40MHz), est adaptée pour des applications sans fil exigeantes telles que l’Ethernet I/O et pour de la vidéo haute résolution.
Le logiciel IH Browser de configuration et de surveillance, inclus avec chaque radio, permet à l’utilisateur de visualiser la topologie du réseau, d’attribuer des adresses IP, de récupérer les diagnostiques réseaux, et de mettre à jour le firmware de la radio.
L’option « OPC Diagnostic Server » est idéale pour la gestion de réseaux SCADA sans fil longue portée.
The Weatherproof IP67 Fast Industrial Hotspot is UL Class 1 Division 2 certified and features an IP66/67 rating. It is water-tight for use in extreme weather applications such as offshore oil rigs, and dust-tight for use in mining applications. It operates in the 2.4 or 5 GHz bands, including DFS channels, and is good for applications up to 2 mi. / 3.2 km. The radio features Ultra-Fast access point switchover times of less than 10 ms, which is ideal for applications such as automated storage-retrieval systems, automotive skillet lines, and bottle filling machines.
The radio will be appreciated by both sides – OT and IT. Your OT personnel will like the radio’s EtherNet/IP embedded object and Modbus agent support, which allows them to get diagnostic data into their PLC immediately, where they can analyze and act upon data, optimizing your resources. IT departments will appreciate the radio’s SNMP support.
The ProSoft Technology 802.11g High Power Industrial Hotspot™ (RLX2-IHG) is a high-speed wireless Ethernet radio for applications up to 10 mi. / 16 km. The RLX2-IHG uses the 2.4 GHz band and supports a data rate up to 54Mbps. The Hotspot supports Access Point, Repeater, Bridging, and Client modes. The RLX2-IHG offers fast roaming, hazardous location certifications, as well as vibration and shock resistance.
The included IH Browser configuration and monitoring software allows the user to view network topology, assign IP addresses, monitor network diagnostics, and update radio firmware.
The 802.11a High Power Industrial Hotspot™ (RLX2-IHA) is a high-speed wireless Ethernet radio for long range applications up to 5 mi. / 8 km. The RLX2-IHA uses the 5 GHz band and supports a data rate up to 54 Mbps. The radio features Ultra-Fast access point switchover times of less than 10 ms, which is ideal for applications such as automated storage-retrieval systems, automotive skillet lines, and bottle filling machines.
The radio will be appreciated by both sides – OT and IT. Your OT personnel will like the radio’s EtherNet/IP embedded object and Modbus agent support, which allows them to get diagnostic data into their PLC immediately, where they can analyze and act upon data, optimizing your resources. IT departments will appreciate the radio’s SNMP support.
Le routeur VPN industriel ICX35-HWC est la solution idéale pour les intégrateurs et les OEM qui doivent prendre la main à distance sur leurs installations. Avec ce module, ils peuvent contrôler et diagnostiquer leurs architectures à travers le monde par le bais du réseau 4G ou 3G.
Un automate communicant en EtherNet/IP™ ou en Modbus TCP/IP peut ainsi envoyer un bloc message en utilisant le routeur ainsi qu’accéder à des données de diagnostic afin d’éviter aux clients de coûteuses visites sur site.
L’outil sécurisé ProSoft Connect, développé par ProSoft Technology, est une solution cloud native utilisée dans le cadre de l’internet des objets industriels (IIOT). Ce service est accessible de n’importe où dans le monde. Il propose aux utilisateurs une interface web intuitive depuis laquelle il peut contrôler son architecture d’automatismes en temps réel.
Vous avez besoin de communiquer avec quelques Entrées et Sorties TOR ou analogiques, mais vous ne pouvez pas justifier le coût d’installation du câblage? Le Kit Radio peut remplacer un système d’Entrées/Sorties câblé et est très facile à installer. Le Kit ne demande aucune programmation – seulement une pince à dénuder et un tournevis. Pas besoin de s’y connaitre en protocole de communication.
Les radios sont livrées configurées et sécurisées, aucune configuration supplémentaire n’est nécessaire. La communication est bidirectionnelle, les signaux TOR ou analogiques peuvent être envoyés dans les deux directions entre deux stations d’Entrées/Sorties. Les entrées d’un module sont simplement répliquées sur les sorties du module correspondant. Le Kit Wireless I/O fonctionne sur la bande ISM en 868 MHz, 900 MHz, ou 2.4 GHz, et est disponible en version US et Internationale. Les radios peuvent envoyer leur signal jusqu'à 6 km pour la version 900 MHz ou 2 km pour les versions 868 MHz et 2.4 GHz. Chaque paire de radios peut connecter jusqu'à 16 modules I/O, suffisant pour la plupart des applications.
ProSoft Technology’s Multi-Point Wireless I/O system allows you to monitor I/O from multiple locations without running long wires. This secure, reliable system is scalable and deploys quickly, allowing you to skip trenching, conduit, and permits. Three module types: Analog 0-10 V, Analog 4-20 mA, and Digital/Discrete – give you the freedom to customize your setup based on your environment and needs.
The system can be used in different methods: I/O to I/O, I/O to Modbus serial communications, and Modbus® serial to Modbus Serial communications. This peer-to-peer system can move data from the I/O or Modbus devices to any other node. The digital input module can act as a counter and send the accumulated value to another location.
The Modbus TCP/IP to IEC 61850 gateway enables communication between the Intelligent Electronic Devices (IEDs) on an IEC 61850 network and Programmable Logic Controllers (PLCs) or Programmable Automation Controllers (PACs) on a Modbus TCP/IP network.
The configuration utility software provided with the gateway uses IED configuration files to import complex IEC 61850 data structures. The utility creates Variable files and Function Block files for import into Unity Pro projects for Quantum or M340 processors.
IEC 61850 is the international standard that defines the hardware and communication requirements for all devices within substation automation. The standardized naming conventions imposed by the IEC 61850 standard improves interoperability between systems provided by diverse manufactures or created by multiple system integrators.
ProSoft Technology provides field-proven connectivity and communication solutions that bridge between various automation products seamlessly
|
|
|
Secure Remote Access SolutionSystem integrators, OEMs, and large end users in particular will appreciate the ease of use that ProSoft Connect offers when it comes to monitoring and programming remote control equipment. With ProSoft Connect, it doesn't matter where you are. All you need is an internet connection! How it helps you...
Save time and money: By being able to monitor and troubleshoot your control equipment in real time from anywhere in the world, you reduce your support travel expenses and you associated time. |
If you listen you can hear warblers and flycatchers in the undeveloped wilderness of northern Ontario. As your ears become attuned to the solitude of this beautiful area of Canada, you will also hear another sound…rushing water, in the local power generating station.
Read StoryWe tend to think about it only when disturbances occur, but wastewater treatment is a basic public service that affects all of us: it is vital to keep our living environment hygienic and healthy and our watercourses clean.
Read StoryWith a pumping station that is 25 stories tall, the Changi Water Reclamation Plant, located on the diamond-shaped island of Singapore, is the cornerstone of the Singapore Deep Water Sewage System.
Read StoryIt’s become quite clear that the Industrial Internet of Things (IIoT) is the future of Industry. By now we’ve well and truly covered the point that IIoT is, in fact, not hype. For end users and OEMs IIoT, cloud and big data analytics are creating very real business opportunities [...]
Read moreThe first key concept in IIoT deployment involves securing systems. Product lifecycle has a huge impact on security in industrial applications. Unlike IT environments, products can remain in active service in industrial control systems for as long as 30 years [...]
Read moreThe Industrial Internet of Things (IIoT) has been a hot topic of late. One key consideration that will impact its acceptance rate and ultimate success is security [...]
Read more