MVI56E Product Photo - DNPNET

DNP3 Ethernet Module for ControlLogix®

MVI56E-DNPNET

The MVI56E DNP3 Ethernet Communication Module allows Rockwell Automation ControlLogix ® PACs to interface on a DNP3 Ethernet network. The module supports operation as an Ethernet Client with up to 40 DNP3 Ethernet server devices such as RTU's, IED's, and various protection relays. With support for 300 user definable commands and a maximum of up to 20,000 points of data, the module can be used to obtain data from a network of devices over a DNP3 Ethernet link.

Additionally the module can simultaneously operate as a DNP3 Ethernet server allowing the unit to interface to other client devices such as SCADA and DCS systems using the DNP3 protocol. With a large event data storage for up to 20,000 time stamped events, the module will buffer event data during a loss of communications with the DNP3 client device, reporting this information when communications has been re-established.

The module utilizes an Add-On Instruction in RSLogix 5000 for the configuration and setup of the module, allowing configuration data to be stored in the PAC ladder code. Remote diagnostics of the unit can be performed using the ProSoft Configuration Builder utility or through controller tags available in RSLogix 5000.

A conformal coating option is available for this product.

Images

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Caractéristiques Avantages

The module utilizes an Add-On Instruction in RSLogix 5000 for the configuration and setup of the module, allowing configuration data to be stored in the PAC ladder code. Remote diagnostics of the unit can be performed using the ProSoft Configuration Builder utility or through controller tags available in RSLogix 5000.

Spécifications

  • Single-slot 1756 ControlLogix backplane compatible
  • 10/100 Mbps auto crossover detection Ethernet configuration and application port
  • User-definable module data memory
  • CIPconnect-enabled network diagnostics monitoring using ControlLogix 1756-ENxT and 1756-CNB modules and EtherNet/IP pass-through communication
  • Add-On Instructions (AOI) are used for data transfer between module and processor
  • ProSoft Discovery Service (PDS) software used to locate the module on the network and assign temporary IP address

Matériel

Specification

Description

Backplane Current Load

800 mA @ 5 V DC
3 mA @ 24 Vdc

Operating Temperature

0° to 60°C (32° to 140°F)

Storage Temperature

-40° to 85°C (-40° to 185°F)

Shock:

30g Operational
50g non-operational

Vibration

5 g from 10 Hz to 150 Hz

Relative Humidity

5 to 95% (non-condensing)

LED Indicator:

Battery Status (ERR)
Application Status (APP)
Module Status (OK)

4-Character Display

Shows Module IP Address

Ethernet Port

10/100 Base-T, RJ45 Connector, for CAT5 cable
Link and Activity LED indicators
Auto-crossover cable detection

Shipped with Unit

5-foot Ethernet straight-through cable

Certifications

CB Safety 504,75 kB Dernière Modification 06/10/2021
IECEx 162,02 kB Dernière Modification 25/05/2016
Declaration of Conformity (RoHS/CE) 136,60 kB Dernière Modification 20/01/2023
ATEX Letter of Conformity 101,65 kB Dernière Modification 12/05/2022
UL CoC 83,45 kB Dernière Modification 23/06/2020
Korean KC Registration 185,94 kB Dernière Modification 11/09/2020
Declaration of REACH Compliance 134,07 kB Dernière Modification 20/05/2022
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1,92 MB Dernière Modification 10/07/2020