The MVI56 Application Development Module is a ControlLogix backplane compatible module that allows user-developed 'C' applications to operate on the ControlLogix platform. A great way to speed up custom ASCII data communications or to protect a proprietary algorithm, the ADM is a powerful tool for the ControlLogix platform.
Powerful platform for developing and running 'C' applications on Rockwell Automation's ControlLogix processors. The MVI56-ADM module is a single slot, backplane compatible solution for the Rockwell Automation ControlLogix platform. This module is a powerful and programmable solution supporting two fully isolated serial ports allowing the many serial field devices to be integrated into the ControlLogix platform.
PRT1 and PRT2 are jumper configured for direct or Multidrop field communication. The application program can be written to control the two application ports independently, allowing maximum flexibility in the design.
The MVI56-ADM module is the ideal solution for many applications where serial connectivity must be added to a ControlLogix platform. Applications using the MVI56-ADM module include:
Specification |
Description |
Backplane Current Load |
800 mA @ 5.1 VDC |
Operating Temperature |
32° F to 140° F (0° C to 60° C) |
Storage Temperature |
-40° F to 185° F (-40° C to 85° C) |
Shock |
30 g Operational |
Vibration |
5 g from 10 to 150 Hz |
Relative Humidity |
5% to 95% (without condensation) |
LED Indicators |
Module Status |
Debug/Configuration port (CFG) |
|
CFG Port (CFG) |
RJ45 (DB-9M with supplied cable) |
Application ports (PRT1 & PRT2) Full hardware handshaking control, providing radio, modem and multi-drop support |
|
Software configurable communication parameters |
Baud rate: 110 to 115,200 baud, depending on protocol RS-232, 485 and 422 Parity: none, odd or even Data bits: 5, 6, 7, or 8 Stop bits: 1 or 2 RTS on/off delay: 0 to 65535 milliseconds |
App Ports (P1,P2) (Serial modules) |
RJ45 (DB-9M with supplied cable) RS-232 handshaking configurable 500 V Optical isolation from backplane |
Shipped with Unit |
RJ45 to DB-9M cables for each port 6-foot RS-232 configuration cable |
ATEX Letter of Conformity | 79,81 kB | Dernière Modification 12/05/2022 |
CB Safety | 41,99 kB | Dernière Modification 26/02/2020 |
Declaration of Conformity (RoHS/CE) | 137,73 kB | Dernière Modification 20/05/2022 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1,92 MB | Dernière Modification 10/07/2020 |
Korean KC Registration | 616,34 kB | Dernière Modification 13/03/2020 |
UL/cUL; Class 1, Div 2 | 1,12 MB | Dernière Modification 27/02/2019 |
UL/cUL; Class 1, Div 2 (Canada) | 1,14 MB | Dernière Modification 27/02/2019 |
Declaration of REACH Compliance | 133,82 kB | Dernière Modification 20/05/2022 |