ProSoft Technology’s EtherNet/IP™ to Siemens® Industrial Ethernet communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™-enabled controllers or devices and Siemens® S7 PACs, including S7-200s, S7-300s, S7-400s, S7-1200 and S7-1500 PACs.
In addition, the gateway includes several features, including data prioritization, that allow for simplified integration, reduced commissioning time and optimized performance.
Specification |
Description |
Number of Class 3 Server Connections |
5 |
Supported PLC Types |
PLC2, PLC5, SLC, CLX, CMPLX, MICROLX |
Supported Message Types |
PCCC and CIP |
Class 3 Client Connections |
Connected - 2 |
Number of Class 1 I/O Connections |
2 |
I/O connection sizes |
248/248 |
Max RPI time |
5 ms per connection |
CIP Services Supported |
0x4C - CIP Data Table Read |
Command List |
Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count. |
Command Sets |
PLC-2/PLC-3/PLC5 Basic Command Set |
Specification |
Description |
|
Supported PLC Data Exchange (Read and Write) |
Siemens S7-200, Siemens S7-300, Siemens S7-400, |
|
Supported Register Types |
DB, Inputs, Outputs, Flags, Counters, Timers |
|
Supported Clients |
20 |
Specification |
Description |
Power Supply |
24 VDC nominal |
Current Load |
24 VDC nominal @ 300 mA |
Operating Temperature |
-25°C to 70°C (-13°F to 158°F) |
Storage Temperature |
-40°C to 80°C (-40°F to 176°F) |
Shock |
IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational) |
Vibration |
IEC 60068-2-6; 5G @ 10 to 150 Hz |
Relative Humidity |
5% to 95% RH with no condensation |
Dimensions (H x W x D) |
5.38 x 1.99 x 4.38 in |
LED Indicators |
Configuration (CFG), Error (ERR), Power (PWR), Hardware Fault (FLT), Network Status (NS), EtherNet/IP™ Class I or Class III Connection Status (EtherNet/IP Only) Module Status (MS), Module Configuration Status (EtherNet/IP Only) Ethernet Communication Port Link/Activity, and 100 mbit |
Ethernet Port |
10/100Mbit half-duplex RJ45 Connector Electrical Isolation 1500 Vrms at 50 to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency is less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration |
Shipped With Each Unit |
2.5 mm screwdriver |
ATEX Letter of Conformity | 107,32 kB | Dernière Modification 12/05/2022 |
CB Safety | 348,30 kB | Dernière Modification 20/10/2022 |
EtherNet/IP Declaration of Conformity | 86,04 kB | Dernière Modification 08/01/2013 |
Korean KC Registration | 974,32 kB | Dernière Modification 07/07/2020 |
UL Certificate of Compliance | 233,35 kB | Dernière Modification 16/11/2022 |
Declaration of Conformity (RoHS/CE) | 114,24 kB | Dernière Modification 01/06/2022 |
ODVA EtherNet/IP - Declaration of Conformity | 183,48 kB | Dernière Modification 09/11/2020 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1,92 MB | Dernière Modification 10/07/2020 |