RadioLinx Lightning Protection is designed to provide protection for broadband wireless, Wi-Fi, and WLAN systems with low RF power and excellent protection for less exposed subscriber units.
The LP-24002 lightning protection is designed for use inside an enclosure with the bulkhead fitting protruding through the enclosure. The connectors are standard N jack connector to standard N jack BH connector. The bulkhead fitting can be connected to any standard N type connector extension cable.
The LP-24003 lightning protection is designed for use inside an enclosure with the bulkhead fitting protruding through the enclosure and connecting to a N plug barrel adapter. This can then connect to any antenna with a standard N type connector.
RadioLinx Lightning Protection is designed to protect the radio in the event of a lightning strike. A minimum 6 gauge copper wire should be used to connect the lightning protection to earth ground.
|    Surge Capabilities  | 
   IEC 1000-4-5, 8/20µs @ 10kA  | 
|    Frequency Range  | 
   2.0 to 6.0 GHz  | 
|    Return Loss  | 
   > 20 dB  | 
|    Insertion Loss  | 
   ≤ 0.2 dB  | 
|    RF Power  | 
   10W  | 
|    Temperature Operating/Storage  | 
   -40°to 85°C  | 
|    Relative Humidity  | 
   0 to 100% condensing  | 
|    Surge Throughput Energy  | 
   ≤ 0.5µJ (6kV/3kA 8/20µs)  | 
|    Peak Let-Through Voltage  | 
   ± 3V (6kV/3kA 8/20µs)  | 
| Lightning Protection Datasheet | 113,56 kB | Dernière Modification 14/12/2009 |