MVI56E-GEC pix

Generic ASCII Ethernet Enhanced Communication Module

MVI56E-GEC

The MVI56E-GEC Generic ASCII Ethernet Interface module is designed to allow ControlLogix® processors to interface easily with ASCII devices using the TCP/IP protocol. Compatible devices may be either ASCII instruments with built-in Ethernet or Ethernet connection via a thin server to the existing ASCII device.

Five Servers and Clients are present on the module permitting both the reception and transmission of data between the processor and attached devices.

Caractéristiques Avantages

  • Single Slot - 1756 backplane compatible
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module.
  • Ladder Logic is used for data transfer between module and processor. Sample ladder file included.
  • Configuration data obtained from configuration text file downloaded to module.
  • Local or remote rack

Spécifications

Functional Specifications

  • Five Servers and five Clients to receive and/or transmit data
  • 10/100 Base-T Ethernet-compatible interface
  • Configurable parameters
    • Service port number
    • Connection timeout
    • Close type
  • Simple ladder logic operation
  • Setup and monitoring through ProSoft Configuration Builder (PCB) software
  • ControlLogix® backplane interface via I/O access
  • Each Server monitors
    • State
    • IP and port number of connected Client
    • Error codes
  • Each Client monitors
    • State
    • IP and port number of connected Server
  • ASCII character strings up to 2048 characters in length supported
  • Module error and status conditions returned to processor for diagnostic purposes
    • Module status
    • Port error status word (bit mapped)
    • Port receive state
    • Port receive character count
    • Port receive block count
    • Port transmit state
    • Port transmit character count
    • Port transmit block count
  • All data related to the module is contained in a single controller tag with defined objects to simplify the configuration, monitoring, and interfacing with the module
  • Communication Data is transferred to the MVI56E-GEC via a pre-defined user data type in the processor

Matériel

Specification

Description

Backplane Current Load

800 mA @ 5 VDC 3 mA @ 24 VDC

Operating Temperature

0°C to 60°C (32°F to 140°F)

Storage Temperature

-40°C to 85°C (-40°F to 185°F)

Shock

30 g operational 50 g non-operational Vibration: 5 g from 10 Hz to 150 Hz

Relative Humidity

5% to 95% RH, with no condensation

LED Indicators

Battery Status (ERR) Application Status (APP) Module Status (OK)

4-Character, Scrolling, Alpha-Numeric LED Display

Shows Module, Version, IP, and Backplane Status

Debug/Configuration/Application Ethernet port (E1)

Ethernet Port

10/100 Base-T, RJ45 Connector, for CAT5 cable

Link and Activity LED indicators

Auto-crossover cable detection

Certifications

Declaration of Conformity (RoHS/CE) 136,60 kB Dernière Modification 20/01/2023
CB Safety 504,75 kB Dernière Modification 06/10/2021
ATEX Letter of Conformity 101,65 kB Dernière Modification 12/05/2022
UL CoC 83,45 kB Dernière Modification 23/06/2020
Declaration of REACH Compliance 134,07 kB Dernière Modification 20/05/2022
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1,92 MB Dernière Modification 10/07/2020