The A-CANBR/B CAN Bus Router provides intelligent data routing between either EtherNet/IP™ or Modbus® TCP/RTU and a CAN Bus network. This allows the user to integrate CAN Bus devices into a Rockwell Automation Logix platform (e.g., ControlLogix® or CompactLogix™) or any Modbus Client or Server device with minimal effort.
The A-CANBR/B also provides a range of statistics, CAN Bus and Modbus packet capture functions, and internal Modbus and Data table reads to simplify remote diagnosis. A built-in webserver provides detailed diagnostics of system configuration and operation, including the display of CAN Bus operation and communication statistics, without the need for any additional software.
| Specification |
Rating |
| Connector |
RJ45 |
| Conductors |
CAT5 STP/UTP |
| ARP Connections |
Max 100 |
| TCP Connections |
Max 100 |
| CIP Connections |
Max 15 |
| Communication Rate |
10/100 Mbps |
| Duplex Mode |
Full / Half |
| Auto-MDIX Support |
Yes |
| Embedded Switch |
Yes, 2x Ethernet ports |
| Device Level Ring (DLR) |
Supported |
| Network Time Protocol (NTP) |
Supported |
| Specification |
Rating |
| RS232 Connector |
9-way terminal (shared with RS485) |
| RS232 Conductor |
24 to 18 AWG |
| Electrical Isolation |
1000 VDC |
| Baud Rate |
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
| Parity |
None, Even, Odd |
| Data Bits |
8 |
| Stop Bits |
1 |
| Specification |
Rating |
| RS485 Connector |
9-way terminal (shared with RS485) |
| RS485 Conductor |
24 to 18 AWG |
| Electrical Isolation |
1500 Vrms for 1 minute |
| Baud Rate |
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
| Parity |
None, Even, Odd |
| Data Bits |
8 |
| Stop Bits |
1 |
| Specification |
Rating |
| Connector |
5-way terminal, 5.08mm pitch. |
| Max CAN Receive Items |
100 |
| Max CAN Send Items |
100 |
| Passthrough Messaging |
Supported |
| Supported Baud Rates |
10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M |
| CAN Terminator |
120 Ω - Software Enabled |
| Specification |
Rating |
| Class 1 Cyclic connection count |
4 |
| Logix Direct-to-Tag Supported |
Yes |
| Specification |
Rating |
| Class 1 Cyclic Connections Supported |
Yes |
| Class 3 / UCMM Connections Supported |
Yes |
| Class 1 Connection Count |
10 |
| Class 3 / UCMM Target Device Count |
10 |
| Class 3 / UCMM Mapping Count |
50 |
| Specification |
Rating |
| Modes Supported |
Modbus TCP, Modbus RTU232, Modbus RTU485 |
| Modbus RTU485 Termination |
125 Ω - Software Enabled |
| Max. Modbus Server Devices |
20 |
| Max. Modbus Mapping |
100 |
| Mapping Ranges |
Holding Register 0 to 65535 |
| Base Offset |
Modbus (Base 0) |
| Configurable Modbus TCP Port |
Yes |
| Data Reformatting Supported |
BB AA |
| Specification |
Rating |
| Modes Supported |
Modbus TCP, Modbus RTU232, Modbus RTU485 (simultaneous) |
| Modbus RTU485 Termination |
Software set |
| Mapping Ranges |
Holding Register 0 to 65535 |
| Base Offset |
Modbus (Base 0) |
| Configurable Modbus TCP Port |
Yes |
| Specification |
Rating |
| Power Supply |
Input: 10 to 32 VDC |
| Power Consumption |
2.2 W (Max.) |
| Dimensions (H x W x D) |
149.0 x 34.0 x 116.0 mm (5.86 x 1.34 x 4.56 in) |
| Connector |
3-way terminal |
| Conductors |
24 to 18 AWG |
| Enclosure Rating |
IP20, NEMA/UL Open Type |
| Temperature |
-20°C to 70°C (-4°F to 158°F ) |
| Humidity |
0 to 95% RH, non-condensing |
| Earth Connection |
Yes, terminal based |
| Emissions |
IEC 61000-6-4 |
| ESD Immunity |
EN 61000-4-2 |
| Radiated RF Immunity |
IEC 61000-4-3 |
| EFT/B Immunity |
EFT: IEC 61000-4-4 |
| Surge Immunity |
Surge: IEC 61000-4-5 |
| Conducted RF Immunity |
IEC 61000-4-6 |
| Certificate of Quality | 415,47 kB | Dernière Modification 05/03/2025 |