PROSOFT CONFIGURATION BUILDER README

ProSoft Configuration Builder 4.8.0.018
README File

This README file contains information you should know before you install or upgrade to ProSoft Configuration Builder 4.8.0.018. This file also contains information that may not be available in other ProSoft documentation. Visit ProSoft Technology for the most current information about the ProSoft Configuration Builder.

IMPORTANT NOTE

Forward Compatibility:

Always back up any PPF files before editing them with a new version of PCB. In some cases, PPF files edited and saved with newer versions of PCB may no longer be compatible with older versions of PCB.
The latest version of PCB is always the recommended platform for the latest functionality support. The current PCB Version is 4.8.0.018.

If upgrading from very old versions of PCB v2.0.2 or earlier:

For the PTQ-PDPMV1 module: The .XSY and .XFM files used by Unity Pro, generated and exported by ProSoft Configuration Builder versions 2.0.7 and newer, are NOT COMPATIBLE or INTERCHANGEABLE with earlier versions of .XSY and .XFM files generated by PCB versions 2.02, or earlier. The newer .XSY and .XFM files contain new Unity Pro data types, function blocks, and data structures that did not exist in the older versions of these files, created by older versions of PCB (please see PCB Version 2.0.7 for specific details).
If upgrading from a PCB version older than v2.0.2, please be sure to verify your PROFIBUS configuration and re-export the Unity Pro .XSY and .XFM processor files and upgrade your Unity Pro project, to be sure you are using the latest enhanced versions of these files.

Compatible Operating Systems

System requirements in this document are subject to change and do not represent a commitment to support any particular software or hardware.

·       Windows 11

·       Windows 10 Pro x64

NOTE: To use PCB with older Windows operating systems, you must be sure to install PCB using the "Run as Administrator" option. To find this option, right-click on the Setup.exe installer program icon. In the context menu, you will see the "Run as Administrator" option. Left-click to use this install option. Be aware, you must install using this option even if you are already logged in as an Administrator on your network or personal computer (PC). Using the "Run as Administrator" option will allow the PCB installer to create folders and files on your PC with proper permissions and security. If you do not use the "Run as Administrator" option, PCB may appear to install correctly; but you will receive numerous, repeating file access errors whenever PCB is running, especially when changing configuration screens. If this happens, to eliminate the errors, you will have to completely uninstall PCB and then re-install using the "Run as Administrator" option.

 

 

Table of Contents

Upgrade Information for PCB version 4.8.0.018 (February 2024)

Known Problems and Limitations

Detailed Reason(s) For Change

Module(s) Affected

New Feature(s)

Previously Released Versions of ProSoft Configuration Builder

PCB version 4.8.0.009

PCB version 4.7.0.002

PCB version 4.7.0.001

PCB version 4.6.0.007

PCB version 4.6.0.002

PCB version 4.6.0.001

PCB version 4.6.0.0

PCB version 4.5.002.0

PCB version 4.5.001.0

PCB version 4.5.0.0

PCB version 4.4.24.24

PCB version 4.4.24.23

PCB version 4.4.24.22

PCB version 4.4.24.10

PCB version 4.4.23

PCB version 4.4.17

PCB version 4.4.15

PCB version 4.4.13

PCB version 4.4.6

PCB version 4.4.4

PCB version 4.4.3

PCB version 4.4.1

PCB version 4.3.5

PCB version 4.3.4

PCB version 4.3.3

PCB version 4.1.2

PCB version 4.1.1

PCB version 4.1.0

PCB version 4.0.4

PCB version 4.0.2

PCB version 2.3.2

PCB version 2.3.1

PCB version 2.2.2

PCB version 2.2.1.9

PCB version 2.2.1

PCB version 2.2.0

PCB version 2.1.9.1

PCB version 2.1.9

PCB version 2.1.8

PCB version 2.1.7

PCB version 2.1.6

PCB version 2.1.5

PCB version 2.1.4

PCB version 2.1.3

PCB version 2.1.2

PCB version 2.1.1

PCB version 2.1.0

PCB version 2.0.15

PCB version 2.0.14

PCB version 2.0.13.1

PCB version 2.0.13

PCB version 2.0.12

PCB version 2.0.11

PCB version 2.0.10

PCB version 2.0.9

PCB version 2.0.8

PCB version 2.0.7

PCB version 2.0.6

PCB version 2.0.5

PCB version 2.0.4

PCB version 2.0.3

PCB version 2.0.2

PCB version 2.0.1

PCB version 2.0.0

PCB version 2.0.0

Upgrade Information for PCB Version 4.8.0.018 (February 2024)

Known Anomalies:

1.    Possible issues with earlier versions of Windows XP and the installation of ProSoft Configuration Manager. If installing ProSoft Configuration Builder in a Win XP OS, make sure the OS is updated with the latest Service Packs and .NET Framework.

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.8.0.018 : (February 2024):

1.    Support for M_BO_TB (ASDU 33) is added in PLX32-MBTCP-104. Now upto 100 M_BO_TB points can be configured in PCB.

2.    Data Conversion functionality is added in PLX32-MBTCP-104. Data can be converted from Int to Float or Float to Int according to requirement.

 

Module(s) Affected

Module

Module Firmware Version

PCB Version

PLX32-MBTCP-104

1.005.019

4.8.0.018

New Feature(s)

The following features were implemented for ProSoft Configuration Builder version 4.8.0.018.

1.    Data conversion feature has been introduced for the PLX32-MBTCP-104, Selecting new parameters: "Int to Float" or "Float to Int" conversion method data will be converted, user can also select operation like multiply, divide, subtraction and addition according to requirement.

2.    M_BO_TB (ASDU 33) support is added.

Previously Released Versions of ProSoft Configuration Builder

ProSoft Configuration Builder version 4.8.0.009(December  2023)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.8.0.009: (December 2023):

3.    The server port range has been extended to 65535, expanding it from the previous limit of 41950 for PLX31-EIP-MBTCP, PLX32-EIP-MBTCP and PLX32-EIP-MBTCP-UA modules.

#

Module Name

Previous Range

Current Range

1

PLX31-EIP-MBTCP

1 to  41950

1 to 65535

2

PLX32-EIP-MBTCP

1 to  41950

1 to 65535

3

PLX32-EIP-MBTCP-UA

1 to  41950

1 to 65535

 

4.    A more detailed definition of the Command Control Register has been provided across all MBTCP gateways for MBTCP client commands.

5.    Implement robust and distinct error handling procedures to address the absence of a response from connected devices within the Ethernet connection, encompassing both gateways and chassis modules.

6.    The 28800 baud rate has been removed from all PLX3x and MVI69 series devices that communicate via serial connections. The modules are:

·       PLX31-EIP-ASCII

·       PLX31-EIP-ASCII4

·       PLX31-EIP-MBS

·       PLX31-EIP-MBS4

·       PLX31-MBTCP-MBS

·       PLX31-MBTCP-MBS4

·       PLX31-PND-MBS

·       PLX31-PND-MBS4

·       MVI69E-MBS

·       MVI69L-MBS

·       MVI69E-GSC

7.    MBTCP client commands comment field can have up to 32 characters, expanding it from previous limit of 10 characters for MVI69E-MBTCP.

8.    Implemented a range check for internal addresses in MNET commands, dependent on the function code.

#

Function Code

Previous Range

Current Range

1

3,4,6 and 16

0 to  79999

0 to 4999

2

1,2,5 and 15

0 to  79999

0 to 79999

 

9.    We can now upload the wattcp.cfg file for MV69-MNET with successful results.

10. Users can now input deadband values below 1 for M_ME_NA, M_ME_NB and M_ME_NC parameters of PLX32-EIP-104.

11. EIP Class 3 commands now work properly for the PLX82-EIP-PNC.

 

Module(s) Affected

Module

Module Firmware Version

PCB Version

All Units

All Versions

4.8.0.009

New Feature(s)

The following features were implemented for ProSoft Configuration Builder version 4.8.0.009.

3.    A Watchdog feature has been introduced for the PLX82-EIP-PNC, incorporating two new parameters: "Watchdog Timeout" and "Watchdog Reset Value".

4.    The Reg count range has been extended to 2000, expanding it from the previous limit of 800 for all MBTCP and MBS supporting PLX3x and MVI69 modules.

#

Module Name

Previous Range

Current Range

1

PLX31-EIP-MBTCP

1 to 800

1 to 2000

2

PLX32-EIP-MBTCP

1 to 800

1 to 2000

3

PLX32-EIP-MBTCP-UA

1 to 800

1 to 2000

4

PLX31-MBTCP-PND

1 to 800

1 to 2000

5

PLX32-MBTCP-PND

1 to 800

1 to 2000

6

PLX31-MBTCP-SIE

1 to 800

1 to 2000

7

PLX32-MBTCP-SIE

1 to 800

1 to 2000

8

PLX32-MBTCP-104

1 to 800

1 to 2000

9

PLX31-MBTCP-MBS

1 to 800

1 to 2000

10

PLX31-MBTCP-MBS4

1 to 800

1 to 2000

11

PLX31-EIP-MBS

1 to 800

1 to 2000

12

PLX31-EIP-MBS4

1 to 800

1 to 2000

13

PLX31-PND-MBS

1 to 800

1 to 2000

14

PLX31-PND-MBS4

1 to 800

1 to 2000

15

MVI69E-MBTCP

1 to 800

1 to 2000

16

MVI69E-MBS

1 to 800

1 to 2000

 

5.    The Address range has been extended to 65535, expanding it from the previous limit of 32767 for SIE clients of PLX3x gateways.

#

Module Name

Previous Range

Current Range

1

PLX31-EIP-SIE

1 to 32767

1 to 65535

2

PLX32-EIP-SIE

1 to 32767

1 to 65535

3

PLX31-MBTCP-SIE

1 to 32767

1 to 65535

4

PLX32-MBTCP-SIE

1 to 32767

1 to 65535

 

6.    Included details on port number, format, tick timings, and port configuration in Data Analyzer for PLX31-EIP-MBS, PLX32-EIP-MBS4, PLX31-EIP-ASCII and PLX32-EIP-ASCII4.

7.    Users can now back up the PROFINET device name on an SD card for the following modules:

·       PLX31-PND-MBS

·       PLX31-PND-MBS4

·       PLX32-EIP-PND

·       PLX31-MBTCP-PND

·       PLX32-MBTCP-PND

ProSoft Configuration Builder version 4.7.0.002(July 2022)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.7.0.002: (July 2022):

1.  Copyright year is updated on the PCB Help/About screen for this version.

Module(s) Affected

Module

Module Firmware Version

PCB Version

All Units

All Versions

4.7.0.002

New Feature(s)

There are no new features implemented for ProSoft Configuration Builder version 4.7.0.002

 

ProSoft Configuration Builder Version 4.7.0.001(June 2022)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.7.0.001: (June 2022):

1.    The parameter range for the Error/Status Pointer has been modified for MVI69E-MBTCP and MVI69L-MBTCP modules. Below are the new applicable ranges.

#

Module Name

Previous Range

Current Range

1

MVI69E-MBTCP

-1 to  9955

-1 to 9992

2

MVI69L-MBTCP

-1 to 435 

-1 to 232

 

2.     If a user is trying to Upload/Download a file from module to PC or vice-versa and the same Subnet does not exist in the network configuration of the user, A warning message “Module cannot be selected, Please create a module temporary IP address within the same subnet as your PC” will be displayed.

3.     For the MVI56E- 61850S, In the Diagnostic Setup screen, now the User will be able to open the drop list  under the Select Communication Type option as (1756 ENBT/Ethernet)

Module(s) Affected

Module

Module Firmware Version

PCB Version

All Units

All Versions

4.7.0.001

MVI69L-MBTCP

All Versions

4.7.0.001

       MVI69E-MBTCP

All Versions

4.7.0.001

       MVI56E-61850S

All Versions

4.7.0.001

New Feature(s)

The following features were implemented for ProSoft Configuration Builder version 4.7.0.001.

1.   Added new parameter Command Control Register Function to Modbus TCP Client Driver for below modules:

·       PLX31-EIP-MBTCP

·       PLX31-MBTCP-MBS

·       PLX31-MBTCP-MBS4

·       PLX31-MBTCP-PND

·       PLX31-MBTCP-SIE

·       PLX32-MBTCP-PND

·       PLX32-MBTCP-104

·       PLX32-MBTCP-SIE

·       PLX32-EIP-MBTCP-UA

·       PLX32-EIP-MBTCP

2.   For PLX31-EIP-PND,  A new parameter “Profinet Device Name” is added in PND Section for PCB Configuration. By this, the PROFINET Device name provided in the Siemens TIA tool will be uploaded to the PCB Configuration file and vice-versa.

ProSoft Configuration Builder Version 4.6.0.007 (January 2022)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.6.0.007: (January 2022):

1. Corrected issue: The user is prompted to select a module if he toggles the upload/download button while a module is not selected.

2.    Corrected issue: If the name of a module was changed from the configuration section, the user was not able to download the configuration for that module.

3. Corrected issue: If the TSAP value is negative in the SIE command for the non-S7-200 command, the Invalid Configuration Error is not thrown.

 

Module(s) Affected

Module

Module Firmware Version

PCB Version

All Units

All Versions

4.6.0.007

PLX32-EIP-MBTCP

All Versions

4.6.0.007

All PLX3x-SIE Units

All Versions

4.6.0.007

 

New Feature(s)

The following features were implemented for ProSoft Configuration Builder version 4.7.0.001.

1. For PLX32-EIP-MBTCP, it is configurable from PCB to enable or disable the remote access.

ProSoft Configuration Builder Version 4.6.0.002 (September 2021)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.6.0.002: (September 2021):

1.     Corrected issue: For the MVI56-104S, PCB shows configurations for the N_BO_NA data types when it should not.

2.   Corrected issue: Reloading exported configuration file to project throws   error and does not rename target module.

3.  Corrected issue: New IP Address did not download to 5204SE-MNET-PDPMV1.

Module(s) Affected

Module

Module Firmware Version

PCB Version

MVI56-104S

All Versions

4.6.0.002

5204SE-MNET-PDPPMV1

All Versions

4.6.0.002

 

New Feature(s)

No new features were implemented for ProSoft Configuration Builder version 4.6.0.002

ProSoft Configuration Builder Version 4.6.0.001 (August 2021)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.6.0.001: (August 2021):

1.    Increase Max Number of E/IP Class 1 Connections to 8 (PLX3-45) (CLONE: PLX3-157, PLX3-85 to PLX3-92)

2.    Corrected issue: Unrealistic 65K limit for Internal Addresses on module with 10K database. (MV69-119)

3.    Corrected issue: When trying to convert old 5201-DFNT-104S   configurations to PLX32-EIP-104, PCB crashes and shuts down (ISW-319)

Module(s) Affected

Module

Module Firmware Version

PCB Version

5201-DFNT-104S

All Versions

4.6.0.001

PLX30 (All)

All Versions

4.6.0.001

MVI69E-MBS

All Versions

4.6.0.001

MVI69E-MBTCP

All Versions

4.6.0.001

MVI56E-MNET

All Versions

4.6.0.001

MVI56E-MNETC

All Versions

4.6.0.001

 

New Feature(s)

No new features were implemented for ProSoft Configuration Builder version 4.6.0.001

ProSoft Configuration Builder Version 4.6.0.0 (June 2020)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.6.0.0: (June 2021):

1.     Addition of new module MVI56E-SMGC

2.     Addition of new module MVI56-SMGC

3.     Enhancement: Backward compatibility to support conversion of legacy module (MVI56-SMGC) to enhanced module (MVI56E-SMGC).

4.     Corrected issue: Unrealistic 65K limit for Internal Addresses on module with 10K database.

5.     Corrected issue: PSW-PCB - ProSoft Configuration Builder not working as it should.

6.      Corrected issue: BUG: Auto Convert from 5201-DFNT-104S to PLX32-EIP-104 is not working correctly for the IP conversion

7.      Corrected issue: Typo found in device overview.

Module(s) Affected

Module

Module Firmware Version

PCB Version

MVI56E-SMGC

All Versions

4.6.0.0

MVI56-SMGC

All Versions

4.6.0.0

PLX30 (All)

All Versions

4.6.0.0

MVI69E-MBS

All Versions

4.6.0.0

MVI69E-MBTCP

All Versions

4.6.0.0

MVI56E-MNET

All Versions

4.6.0.0

MVI56E-MNETC

All Versions

4.6.0.0

PLX32-EIP-104

All Versions

4.6.0.0

 

New Feature(s)

No new features were implemented for ProSoft Configuration Builder version 4.6.0.0

ProSoft Configuration Builder Version 4.5.002.0 (October 2020)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.5.002.0: (October 2020):

1.     Corrected issue: Conversion from 5201 to PLX32 does not bring over IP settings.

2.     Corrected issue: Fixed the issue of 5507-HART-PDPS .cfg file is incorrect (missing part of Fixed Data).

Module(s) Affected

Module

Module Firmware Version

PCB Version

PLX32-EIP-104

All Versions

4.5.002.0

PLX32-MBTCP-104

All Versions

4.5.002.0

 

New Feature(s)

No new features were implemented for ProSoft Configuration Builder version 4.5.002.0

ProSoft Configuration Builder Version 4.5.001.0 (September 2020)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.5.001.0: (September 2020):

1.     Corrected issue: Fixed the issue of Module Definitions missing from at least half of the supported modules.

2.     Corrected issue: Fixed the issue of 5507-HART-PDPS .cfg file is incorrect (missing part of Fixed Data).

3.     Corrected issue: Fixed the issue of Mapping a PLX32-EIP-SIE command shows error regarding IP address set.

4.     Corrected issue: Fixed the issue of PCB where my_ip_1 changed to default after upload from module.

Module(s) Affected

Module

Module Firmware Version

PCB Version

All Units

All Versions

4.5.001.0

5507-HART-PDPS

All Versions

4.5.001.0

PLX32-EIP-SIE

All Versions

4.5.001.0

MVI56E-FLN

All Versions

4.5.001.0

 

New Feature(s)

No new features were implemented for ProSoft Configuration Builder version 4.5.001.0

ProSoft Configuration Builder Version 4.5.0.0 (August 2020)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.5.0.0: (August 2020):

1.     Addition support of module PLX32-EIP-104.

2.     Addition support of module PLX32-MBTCP-104.

3.     Enhancement: Database update to support 10,000 Database addresses.

4.     Enhancement: Backward compatibility to support conversion of legacy module (5201-DFNT-104S) to enhanced module (PLX32-EIP-104).

5.     Enhancement: Backward compatibility to support conversion of legacy module (5201-MNET-104S) to enhanced module (PLX32-MBTCP-104).

Module(s) Affected

Module

Module Firmware Version

PCB Version

All Units

All Versions

4.5.0.0

5201-DFNT-104S

All Versions

4.5.0.0

5201-MNET-104S

All Versions

4.5.0.0

PLX32-EIP-104

All Versions

4.5.0.0

PLX32-MBTCP-104

All Versions

4.5.0.0

 

New Feature(s)

The following new feature was implemented for ProSoft Configuration Builder version 4.5.0.0

1.     Implementation of new UI for Ethernet Configuration for PLX32-EIP-104 and PLX32-MBTCP-104.

2.     Implementation of “Number of ports” selection feature for PLX32-EIP-104 and PLX32-MBTCP-104.

ProSoft Configuration Builder Version 4.4.24.24 (May 2020)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.4.24.24: (May 2020):

1.   Corrected issue: Fixed the issue of no GUI indication for the dialog boxes that resizable. Added a gripper in the bottom right corner.

2.     Corrected issue: Fixed the delete confirmation Message box when any module is being deleted.

3.     Corrected issue: Fixed the issue of the range of internal address for different Modbus Function value in MVI56E-MNETC. Corrected issue: Fixed the issue of data flashing to zero when counts under 60 (AOI issue).

4.     Corrected issue: Fixed assigning temporary IP Address in ProSoft Discovery Service.

Module(s) Affected

Module

Module Firmware Version

PCB Version

All Units

All Versions

4.4.24.24

MVI56E-MNETC

All Versions

4.4.24.24

 

New Feature(s)

No new features were implemented for ProSoft Configuration Builder version 4.4.24.24

ProSoft Configuration Builder Version 4.4.24.23 (March 2020)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.4.24.23: (March 2020):

1.     Corrected issue: Fixed the uploading issues when uploading from a different PLX82-EIP/MBTCP-PNC module to a new project that has a PLX82-EIP/MBTCP-PNC module already pre-configured.

2.     Corrected issue: Fixed PCB download/upload issue over high-latency networks

3.     Corrected issue: Fixed the issue of PCB keeps existing PROFIBUS DP configuration for the MVI56-PDPMV1, PTQ-PDPMV1, MVI69-PDPMV1.

4.     Corrected issue: Fixed the issue when upload is performed on a module, it prompts for save as dialogue, saving the new uploaded project overwrites the old project file.

Module(s) Affected

Module

Module Firmware Version

PCB Version

All Units

All Versions

4.4.24.23

ALL PDPMV1 platform units

All Versions

4.4.24.23

ALL PNC platform units

All Versions

4.4.24.23

 

New Feature(s)

No new features were implemented for ProSoft Configuration Builder version 4.4.24.23

ProSoft Configuration Builder Version 4.4.24.22 (March 2020)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.4.24.22: (March 2020):

1.        Enhancement: Added support for the MVI56E-GEC product. It supports the conversion between MVI56-GEC and MVI56E-GEC.

2.        Enhancement: Added support for the MVI69E-GEC product. It supports the conversion between MVI69-GEC and MVI69E-GEC.

3.        Enhancement: Added support for the MVI69E-GSC product. It supports the conversion between MVI69-GSC and MVI69E-GSC.

4.        Enhancement: Added Legacy support to MVI69E-MBS. It allows user to convert their existing MVI69-MCM product configuration from Legacy to the new MVI69E-MBS Enhanced product.

5.        Enhancement: Added Legacy support to MVI69E-MBTCP. It allows user to convert their existing MVI69-MNET product configuration from Legacy to the new MVI69E-MBTCP Enhanced product.

6.        Enhancement: Added field “Mode: Legacy” when MVI69E-MBS and MVI69E-MBTCP are configured in Legacy mode.

7.        Enhancement: Improved filtering in the module selection dialogue .

8.        Corrected issue: Fixed Download issue with 5204-DFNT-PDPMV1.

9.        Corrected issue: Fixed the issue if user has a module selected and clicks 'New' file but selects 'Cancel', module select window still appears.

10.     Corrected issue: Fixed the issue If TSAP value is empty in the SIE command for non-S7-200 command reports -45 error.

11.     Corrected issue: Fixed the issue of PCB not reporting subnet warnings for the PLX32 Series Gateways if the User makes the mistake of setting both ETH ports on the same IP Subnet.

12.     Corrected issue: Set the limit of 80 characters for module name.

13.     Corrected issue: Added the warning if server port value is configured as 80 for MVI56E-GEC and MVI69E-GEC modules.

Module(s) Affected

Module

Module Firmware Version

PCB Version

All Units

All Versions

4.4.24.22

5204-DFNT-PDPMV1

All Versions

4.4.24.22

ALL PLX32 platform units

All Versions

4.4.24.22

MVI56E-GEC

All Versions

4.4.24.22

MVI69E-GEC

All Versions

4.4.24.22

MVI69E-MBS

1.10.021

4.4.24.22

MVI69E-MBTCP

1.10.007

4.4.24.22

 

New Feature(s)

No new features were implemented for ProSoft Configuration Builder version 4.4.24.22

ProSoft Configuration Builder Version 4.4.24.10 (October 2019)

Detailed Reason(s) For Change

The following changes were implemented for PCB v4.4.24.10: (October 2019):

1.   Corrected issue: Issue when creating Multiple PLX82-EIP/MBTCP-PNC modules in the same project. PCB now creates individual fdt project files with an ending suffix value

2.    Corrected issue: PCB downloads correct wattcp.cfg file to MVI56E modules

3.    Corrected issue: Fixed download issue with MVI69-DFCM

4.    Corrected issue: Fixed MVI69x-MBTCP Function Code 5 command bit write in Pass-Through Mode

5.    Corrected issue: Fixed incorrect description in Message Box for PROFINET modules

6.    Corrected issue: Adding a Project by Right-click deletes and/or closes entire project file

7.    Corrected issue: Internal address range for SIE protocol was changed

8.    Change to database: PCB missing setting for Modbus Pass-Through (PLX31-MBTCP-MBS)

9.    Change to database: Updated PCB parameter definition for SIE protocol modules regarding the TSAP value for non-S7-200 commands

10. Change to database: Fixed database description for MVI56E-MNETC

11. Change to database: Fixed database Slave Address definition for most Modbus TCP/IP devices

12. Change to database: Fixed database configuration for PLX82-EIP-PNC Class3 Commands

13. Change to database: Fixed database configuration for SIE Client commands - Command Error Delay Upper Limit

14. Change to database: Fixed database coil address limit for the MVI69E-MBTCP

15. Enhancement: Added Module descriptions to PCB for more products

16. Enhancement: Improved PCB creation of controller tags, by removing hyphens from the module name which are consider invalid by RSLogix

17. Enhancement: Extended the maximum register count for SIE commands from 122 to 222, allowing for SIEMENS processor upper limit

Module(s) Affected

Module

Module Firmware Version

PCB Version

All units

All versions

4.4.24

PLX31-MBTCP-MBS

1.04.008

4.4.24

MVI69-DFCM

1.70

4.4.24

PLX31-MBTCP-MBS

1.04.003

4.4.24

PLX31-EIP-SIE

1.04.003

4.4.24

 

MVI69x-MBTCP/MBS AOI Upgrade

Module

AOI Version

PCB Version

MVI69x-MBTCP

1.4

4.4.24

MVI69x-MBS

1.3

4.4.24

 

New Feature(s)

The following new feature was implemented for ProSoft Configuration Builder version 4.4.24

  1. Implemented new configuration parameters for the PLX31-MBTCP-MBS PassThrough functionality

ProSoft Configuration Builder Version 4.4.23 (January 2019)

Detailed Reasons(s) For Change - v4.4.23

The following changes were implemented for ProSoft Configuration Builder version 4.4.23 (January 2019):

1.    Corrected issue: Upload of module's configuration is identified in PCB as incorrect module type .

2.    Corrected issue: Clicking on Configure deletes path and/or deletes Profibus configuration for the 5204-DFNT-PDPMV1 unit .

3.    Corrected issue: User is no longer required to run the PCB Installation as Administrator.