# PTQMCM.CFG # # This file contains the configuration for the MVI69-MCM communication module. # # LOCATION : Test Bench # DATE : 10/14/2005 # CONFIGURED BY : JA # MODIFIED : # # This section is used to define the configuration for the Module level # data. # [Module] Module Type : PTQ-MCM Module Name : Test Example of PTQ-MCM Communication Module [Backplane Configuration] #These values are required to define the data area to transfer between the module #and the processor. Read Register Start : 0 #Database start register to move to processor Read Register Count : 100 #Number of words moved from module to processor Write Register Start : 500 #Database start register where data placed from processor Write Register Count : 100 #Number of words moved from processor to module #Used to define the area in the Processor for the module to interface with 3x Register Start : 1 #3x start register where data moved from module to processor (1-n) 4x Register Start : 1 #4x start register where data moved from processor to module (1-n) Initialize Output Data : No #Initialize the database file on startup Failure Flag Count : 0 # Error/Status Block Pointer : 3000 #Number of register to store error and status # # This section is used to define the port 1 configuration for the MCM device # [MCM Port 1] Enable : Yes #No=Port Disabled,Yes=Port Enabled Type : 5 #Type of port (0=Master, 1=Slave, 2=Block PT, 3=Block PT Swap, 4=Direct PT, 5=Direct PT Swap) Pass Thru Address : 300 #Address where pass-thru block id is used only Type equal to 2 or 3 Float Flag : No #Float Flag (No=No Floating Point Data, Yes=Use Floating Point Data) Float Start : 4000 #The first register of floating-point data. Float Offset : 2000 #Internal DB offset to start of floating point data Protocol : r #ASCII or RTU Baud Rate : 192 #Baud rate for port (300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115(for 115200)) Parity : None #N=None,O=Odd,E=Even Data Bits : 8 #7 or 8 data bits for messages Stop Bits : 1 #1 or 2 stop bits for messages RTS On : 0 #Delay after RTS set before message sent (mSec) RTS Off : 0 #Delay after message before RTS dropped (mSec) Minimum Response Delay : 0 #Number of mSec to delay before response Use CTS Line : No #Monitor CTS modem line (Y/N) Slave Address : 1 #0-255 Slave Node Address Bit Input Offset : 0 #Internal DB offset to bit input data (Slave) Word Input Offset : 0 #Internal DB offset to word input data (Slave) Output Offset : 0 #Internal DB offset to bit output data (Slave) Hold Offset : 0 #Internal DB offset to bit output data (Slave) Command Count : 3 #Command list count (Master) Min Cmd Delay : 1 #Minimum time between each command (Master 0-65535) Cmd Err Pointer : 4500 #Internal DB location to place command error list (Master 0-4900) Response Timeout : 0 #Response timeout for command (Master) Retry Count : 2 #Retry count for failed request (Master) Error Delay Count : 0 #Command cycle count if error (Master) [Modbus Port 1 Commands] # Internal Poll Reg Swap Node Modbus MB Address # Enable Address Interval Count Code Address Func in Device START 2 400 0 10 0 1 16 500 2 500 0 10 0 0 16 500 2 5000 0 10 0 1 15 1000 2 700 0 1 0 1 6 1020 2 4000 0 10 0 1 3 0 END # This section is used to define the port 2 configuration for the MCM device # [MCM Port 2] Enable : Yes #No=Port Disabled,Yes=Port Enabled Type : 0 #Type of port (0=Master, 1=Slave, 2=PT Formatted, 3=PT Formatted Swap) Pass Thru Address : 500 #Address where pass-thru block id is used only Type equal to 2 or 3 Float Flag : No #Float Flag (No=No Floating Point Data, Yes=Use Floating Point Data) Float Start : 3000 #The first register of floating-point data. Float Offset : 2000 #Internal DB offset to start of floating point data Protocol : r #ASCII or RTU Baud Rate : 115 #Baud rate for port (300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115(for 115200)) Parity : None #N=None,O=Odd,E=Even Data Bits : 8 #7 or 8 data bits for messages Stop Bits : 1 #1 or 2 stop bits for messages RTS On : 0 #Delay after RTS set before message sent (mSec) RTS Off : 0 #Delay after message before RTS dropped (mSec) Minimum Response Delay : 1 #Number of mSec to delay before response Use CTS Line : No #Monitor CTS modem line (Y/N) Slave Address : 1 #0-255 Slave Node Address Bit Input Offset : 0 #Internal DB offset to bit input data (Slave) Word Input Offset : 0 #Internal DB offset to word input data (Slave) Output Offset : 0 #Internal DB offset to bit output data (Slave) Hold Offset : 0 #Internal DB offset to bit output data (Slave) Command Count : 2 #Command list count (Master) Min Cmd Delay : 0 #Minimum time between each command (Master 0-65535) Cmd Err Pointer : 4600 #Internal DB location to place command error list (Master) Response Timeout : 1 #Response timeout for command (Master) Retry Count : 0 #Retry count for failed request (Master) Error Delay Count : 0 #Command cycle count if error (Master) [Modbus Port 2 Commands] # Internal Poll Reg Swap Node Modbus MB Address # Enable Address Interval Count Code Address Func in Device START 0 0 0 10 0 1 3 0 0 10 0 10 0 1 4 10 END