The MVI56 PROFIBUS DP Slave Communication Module allows ControlLogix I/O compatible processors to interface easily with a PROFIBUS DP Master device.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the module and a ControlLogix processor. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
The MVI56 module Configuration/Debug Serial port connects a PC to the module for configuration, status, monitoring, and troubleshooting (serial cable is included with product shipment). After editing on a PC, a configuration file is downloaded and stored on the MVI56 module.
The PROFIBUS DP Slave gives access to the unit's input and output images with up to 122 words of Input and Output data. Total input and output may not exceed 200 words. These Input and Output data blocks are mapped by the user within the module's data memory allowing maximum flexibility and data transfer with other protocols.
With the growing usage of the PROFIBUS DP protocol in the industrial marketplace, this product has a wide variety of application uses. Industries that use this technology include:
PROFIBUS Slave
Specification |
Description |
Backplane Current Load |
800 mA @ 5.1 VDC |
Operating Temperature |
32° F to 140° F (0° C to 60° C) |
Storage Temperature |
-40° F to 185° F (-40° C to 85° C) |
Shock |
30 g Operational |
Vibration |
5 g from 10 to 150 Hz |
Relative Humidity |
5% to 95% (without condensation) |
LED Indicators |
Module Status |
Debug/Configuration port (CFG) |
|
CFG Port (CFG) |
RJ45 (DB-9M with supplied cable) |
Application ports (PRT1 & PRT2) Full hardware handshaking control, providing radio, modem and multi-drop support |
|
Software configurable communication parameters |
Baud rate: 110 to 115,200 baud, depending on protocol RS-232, 485 and 422 Parity: none, odd or even Data bits: 5, 6, 7, or 8 Stop bits: 1 or 2 RTS on/off delay: 0 to 65535 milliseconds |
App Ports (P1,P2) (Serial modules) |
RJ45 (DB-9M with supplied cable) RS-232 handshaking configurable 500 V Optical isolation from backplane |
Shipped with Unit |
RJ45 to DB-9M cables for each port 6-foot RS-232 configuration cable |
ATEX Letter of Conformity | 79,81 kB | Dernière Modification 12/05/2022 |
CB Safety | 41,99 kB | Dernière Modification 26/02/2020 |
Declaration of Conformity (RoHS/CE) | 137,73 kB | Dernière Modification 20/05/2022 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1,92 MB | Dernière Modification 10/07/2020 |
Korean KC Registration | 2,44 MB | Dernière Modification 13/03/2020 |
UL/cUL; Class 1, Div 2 | 1,12 MB | Dernière Modification 27/02/2019 |
UL/cUL; Class 1, Div 2 (Canada) | 1,14 MB | Dernière Modification 27/02/2019 |
Declaration of REACH Compliance | 133,82 kB | Dernière Modification 20/05/2022 |