PLX31_MBTCP_MBS4

EtherNet/IP to ASCII 4 Port

PLX31-EIP-ASCII4

ProSoft Technology’s EtherNet/IP™ to ASCII four-port communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™-enabled PACs and ASCII devices such as weigh scales and barcode readers. The EtherNet/IP™ protocol driver supports the explicit messaging implementation. The gateway is userconfigurable as both a client and a server.

EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and CompactLogix™, as well as several Schneider Electric® controllers. Applications for this module are found in most industries, especially manufacturing, oil & gas, electrical power and food processing. 

The gateway has several features that allow for simplified integration, reduced commissioning time and optimized performance.

Images

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Caractéristiques Avantages

  • 4000 Word database
  • Multiple I/O Connections
  • Status data
  • Node Health
  • 10/100 Mb Ethernet port with Auto Cable Crossover Detection
  • Data Analyzer for ASCII Network

Matériel

Spécification

Description

Alimentation

24 Vdc nominal

10 Vdc à 36 Vdc autorisé

(+, -, GND)

 Intensité 

24 Vdc nominal à 300mA
10 à 36 Vdc à 610mA maximum

Température de fonctionnement

-25°C à 70°C (-13°F à 158°F )

Température de stockage

-40°C à 80°C (-40°F à 176°F )

Humidité relative

5% à 95% (sans condensation)

Chocs

IEC 60068-2-27; 15g à 11ms, 3-Axis (Opérationel)
IEC 60068-2-27; 30g à 18ms, 3-Axis (Non-Opérationel)

Vibration

IEC 60068-2-6; 5g de 10Hz à 150Hz

Dimensions
(H x L x P)

Standard: 13.67 cm x 5.05 cm x 11.13 cm
(5.38 in x 1.99 in x 4.38 pouces)

Témoins à DEL

Configuration (CFG), Erreur (ERR), Puissance (PWR), Erreur matérielle (FLT), Etat de l’application (NS),  Statut de connexion EtherNet/IP™ Class I ou Class III (EtherNet/IP Only), Etat du module (MS),  Etat port Ethernet avec connectivité/activité, 100Mbit réception sur port série (RX) et émission (TX)

Port Ethernet

10/100Mbit half-duplex. Connecteur RJ45. Isolation électrique spécifiée dans la section 5.3.2 du IEC 60950: 1991. Ethernet Broadcast Storm Resiliency: inférieure ou égale à 5000 [ARP] frames-per-second et inférieure ou égale à une durée de 5 minutes.

Port(s) Série

Note: Le nombre de port série dépend du type de passerelle, et de la combinaison de protocoles.

Isolation port série

2500 Vrms port signal isolation per UL 1577 serial port communication signal uses RF (Radio Frequency) modulation signal as isolation media, IC chip model is SiliconLabs Si844x (Si8440, Si8441, Si8442)

Fourni avec chaque passerelle

Tournevis 2.5 mm, Connecteur d’alimentation J180,
(1 à 4) Câble RJ45-DB9M,
(1 à 4) Connecteur à vis / DB9 (protocole série),
Câble droit Ethernet 152 cm (5 pieds)

Protocoles

Spécifications Protocole PLX30-EIP


Protocol Specifications

Spécifications EtherNet/IP® 

Nombre de connexions Serveur de Classe 3

5

Types d’API supportés

PLC2, PLC5, SLC, CLX, CMPLX, MICROLX 

Messagerie

PCCC et CIP

Nombre de connexions Client de Classe 3

 

Connecté
Non connecté

2
1

Nombre de connexions E/S de Classe 1

 

PLX31-EIP-MBTCP/MBS
PLX31-EIP-MBS4
PLX31-EIP-ASCII
PLX31-EIP-ASCII4
PLX31-EIP-SIE

2
8
1
4
2

Taille des connexions E/S

248/248

RPI maximum

5ms par connexion

Services CIP supportés

0x4C - Lecture de la table de données CIP
0x4D - Ecriture dans la table de données CIP

Liste de commandes

Supporte 100 commandes, chacune est configurable pour la commande, l’adresse IP, les registres d’adressage, le comptage mot/bit.

Commandes supportées

Commande basique pour PLC-2/PLC-3/PLC5
Commande binaire pour PLC5
Commande pour PLC5 ASCII
Commande pour SLC500

 

Spécifications Modbus TCP/IP 

Codes fonctions Modbus

1: Lecture de bit 
2: Lecture de bit d'entrée
3: Lecture de mot
4: Lecture de mot d'entrée
5: Ecriture de bit
6: Ecriture de mot

15: Ecriture de multiples bits 
16: Ecriture de multiples mots
22: Ecriture avec masque de mot (Esclave seulement) 
23: Lecture/Ecriture de mot (Esclave seulement)

Clients supportés

10

Serveurs supportés

 

MBAP
Encapsulaté

5
5

 

Liste de commandes

Jusqu’à 160 commandes Client entièrement configurable

Données d’état

Codes d’erreur disponibles sur la base de commandes individuelles

Envoi de commandes

Les commandes peuvent être envoyées de façon continue ou sur changement de valeur (écriture seulement) 

 

Spécifications Modbus série 

Liste de commandes

Supporte 100 commandes, chacune est configurable pour la commande, l’adresse IP, les registres d’adressage, le comptage mot/bit.

Codes fonctions Modbus

1: Lecture de bit 
2: Lecture de bit d'entrée
3: Lecture de mot
4: Lecture de mot d'entrée
5: Ecriture de bit
6: Ecriture de mot

15: Ecriture de multiples bits 
16: Ecriture de multiples mots
22: Ecriture avec masque de mot (Esclave seulement) 
23: Lecture/Ecriture de mot (Esclave seulement)

Paramètres de configuration du logiciel

Débit: 110 baud à 115.2 kbps. Parité: aucune, paire ou impaire. Taille de donnée: 7 ou 8 bits. Bits d’arrêt: 1 ou 2 . Délai de temporisation RTS: 0 à 65535 millisecondes. Modes RTU (binaire) avec CRC-16. Mode ASCII avec LRC. Données flottantes : Format Enron / Daniel implémenté.

Envoi de commandes

Les commandes peuvent être envoyées de façon continue ou sur changement de valeur (écriture seulement) Activation/désactivation dynamique des commandes via EtherNet/IP.

Données d’état 

Codes d’erreur disponibles sur la base de commandes individuelles. En complément, une liste d’état esclave est maintenue par port maître Modbus.

Adresse de nœud 

1 à 247 (sélectionnable via le logiciel)

Interface RS

RS232, RS422, et RS485

 

Spécifications ASCII

Suivant la version choisie de 1 à 4 Ports peuvent transmettre et recevoir des données ASCII.

Mémoire tampon

La mémoire tampon pour recevoir et transmettre des données a une taille de 255 octets. Un délai de 0 à 65535 ms peut être configuré entre chaque octet transmis.

 

Spécifications Siemens Industrial Ethernet 

Spécification

Description

PLC Data Exchange (Read and Write) supportés

Siemens S7-200, Siemens S7-300, Siemens S7-400,
Siemens S7-1200

Types de registres supportés

DB, Inputs, Outputs, Flags, Counters, Timers

Clients supportés

20


ASCII Protocol Specification


The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network.


Protocol Specifications

The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc).

The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both.

ASCII Specifications

Ports

Available in up to four port configurations to receive and/or transmit data.

Transmit and Receive buffer size

255 bytes each

Transmit character with pacing

0 to 65535 millisecond delay between each transmitted character.


Certifications

Ex Certificate (ATEX Directive) 84,06 kB Dernière Modification 22/05/2015
CB Safety 327,80 kB Dernière Modification 22/05/2015
Declaration of Conformity (RoHS/CE) 296,91 kB Dernière Modification 04/03/2018
EtherNet/IP Declaration of Conformity 86,04 kB Dernière Modification 08/01/2013
Korean KC Registration 548,37 kB Dernière Modification 22/05/2015
UL/cUL; Class 1, Div 2 67,02 kB Dernière Modification 19/03/2013