Printer friendly version of this page. Find a Distributor near you.
PLX31-EIP_MBS

EtherNet/IP to ASCII

PLX31-EIP-ASCII

ProSoft Technology’s EtherNet/IP™ to ASCII communication gateway allows highspeed bi-directional data transfers between EtherNet/IP™-enabled PACs and ASCII devices such as weigh scales and barcode readers. The EtherNet/IP™ protocol driver supports the explicit messaging implementation. The gateway is user-configurable as both a client and a server.

EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and CompactLogix™, as well as several Schneider Electric® controllers. Applications for this module are found in most industries, especially manufacturing, oil & gas, electrical power and food processing.

The gateway has several features that allow for simplified integration, reduced commissioning time and optimized performance.

Images

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Caractéristiques Avantages

  • 4000 Word database
  • Status data
  • Node Health
  • 10/100 Mb Ethernet port with Auto Cable Crossover Detection
  • Data Analyzer for ASCII Network

Matériel

Spécification

Description

Alimentation

24 Vdc nominal

10 Vdc à 36 Vdc autorisé

(+, -, GND)

 Intensité 

24 Vdc nominal à 300mA
10 à 36 Vdc à 610mA maximum

Température de fonctionnement

-25°C à 70°C (-13°F à 158°F )

Température de stockage

-40°C à 80°C (-40°F à 176°F )

Humidité relative

5% à 95% (sans condensation)

Chocs

IEC 60068-2-27; 15g à 11ms, 3-Axis (Opérationel)
IEC 60068-2-27; 30g à 18ms, 3-Axis (Non-Opérationel)

Vibration

IEC 60068-2-6; 5g de 10Hz à 150Hz

Dimensions
(H x L x P)

Standard: 13.67 cm x 5.05 cm x 11.13 cm
(5.38 in x 1.99 in x 4.38 pouces)

Témoins à DEL

Configuration (CFG), Erreur (ERR), Puissance (PWR), Erreur matérielle (FLT), Etat de l’application (NS),  Statut de connexion EtherNet/IP™ Class I ou Class III (EtherNet/IP Only), Etat du module (MS),  Etat port Ethernet avec connectivité/activité, 100Mbit réception sur port série (RX) et émission (TX)

Port Ethernet

10/100Mbit half-duplex. Connecteur RJ45. Isolation électrique spécifiée dans la section 5.3.2 du IEC 60950: 1991. Ethernet Broadcast Storm Resiliency: inférieure ou égale à 5000 [ARP] frames-per-second et inférieure ou égale à une durée de 5 minutes.

Port(s) Série

Note: Le nombre de port série dépend du type de passerelle, et de la combinaison de protocoles.

Isolation port série

2500 Vrms port signal isolation per UL 1577 serial port communication signal uses RF (Radio Frequency) modulation signal as isolation media, IC chip model is SiliconLabs Si844x (Si8440, Si8441, Si8442)

Fourni avec chaque passerelle

Tournevis 2.5 mm, Connecteur d’alimentation J180,
(1 à 4) Câble RJ45-DB9M,
(1 à 4) Connecteur à vis / DB9 (protocole série),
Câble droit Ethernet 152 cm (5 pieds)

Protocoles

Spécifications Protocole EIP


Spécifications Protocole EIP


Protocol Specifications

EtherNet/IP Serveur

En mode Serveur, la passerelle accepte les commandes d'un ou plusieurs Clients pour lire/écrire les données stockées dans les registres internes de la passerelle.

Nombre de connexions 

5

Types d’API supportés

PLC2, PLC5, SLC, CMPLX, MICROLX 

Base de données interne

Data Table File Size: 100 or 1000 words

Data Table File Start: N10 to N109 (based on file size set to 100) or

N10 to N19 (based on file set to 1000)

Services CIP supportés

0x4C - CIP Data Table Read

0x4D - CIP Data Table Write

EtherNet/IP Client

En mode Client, la passerelle contrôle le transfert de données lecture/écriture entre la passerelle et les autres équipements EtherNet/IP.

Nombre de Clients supportés

1

Liste de commandes

Supporte 100 commandes, chacune est configurable pour la commande, l’adresse IP, les registres d’adressage, le comptage mot/bit.

Envoi de commandes

Les commandes peuvent être envoyées de façon continue ou sur changement de valeur (écriture seulement) 

Autres paramètres configurables

Nombre de commandes (jusqu'à 100 par Client)

Min Command Delay

Response timeout

Retry Count

Command Error Pointer


ASCII Protocol Specification


The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network.


Protocol Specifications

The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc).

The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both.

ASCII Specifications

Ports

Available in up to four port configurations to receive and/or transmit data.

Transmit and Receive buffer size

255 bytes each

Transmit character with pacing

0 to 65535 millisecond delay between each transmitted character.


Certifications

Ex Certificate (ATEX Directive) 84,06 kB Dernière Modification 22/05/2015
CB Safety 327,80 kB Dernière Modification 22/05/2015
Declaration of Conformity (RoHS/CE) 296,56 kB Dernière Modification 28/09/2017
EtherNet/IP Declaration of Conformity 86,04 kB Dernière Modification 08/01/2013
Korean KC Registration 548,37 kB Dernière Modification 22/05/2015